Body Composition Testing

Changes in body composition can be determinants of successful performance, and there are several methods of body composition testing.

Charlie Beestone

By Charlie Beestone
Last updated: March 1st, 2024
12 min read

Contents of Article

  1. Summary
  2. What does body composition mean?
  3. What is body composition testing?
  4. How is body composition measured?
  5. Are there any issues with body composition testing?
  6. Is future research needed with body composition?
  7. Conclusion
  8. References
  9. About the Author

Summary

Body composition is an area of interest in the fields of both health and sporting performance. In health, body composition has long been of interest, potentially more so with the excessive fat mass evident in obese populations, and the limited skeletal muscle mass in the elderly. In athletic performance, changes in body composition such as reduced fat mass and increased fat-free mass are often highlighted as determinants of successful performance, and the target of multiple interventions.

Over the years, several methods of body composition measurement have been suggested and used, each method likely to have application in certain scenarios, with a trade-off usually occurring between accuracy and reliability, and cost and practicality.

Skinfold Body Fat Test. Measuring Body Fat on Subscapular Tissue Using Caliper.

What does body composition mean?

The term body composition relates to the proportion of the body that is made up of fat mass (FM) and fat-free mass (FFM) (1).  In 1992, Wang et al. (1992) (2) proposed a five-level model for body composition research:

  1. Atomic level
  2. Molecular level
  3. Cellular level
  4. Tissue-organ level
  5. Whole-body level

Each level has different compartments and can be separated into two, three or four compartments. How these compartments are measured and/or estimated varies, and will be elaborated on later in this article.

What is body composition testing?

Body composition provides objective data that is unobtainable from scale weight alone, such as the proportion of weight that is fat mass. For example, a coach may single out an individual as overweight based on scale weight or BMI. However, being heavier may be an advantage in some sports, if a greater proportion of the weight is skeletal muscle mass (e.g. a forward in rugby union). Body composition may also have application in weight-making sports, to determine the respective loss of FM and FFM during weight-cutting for a competition (3).

In runners, an emphasis is placed on the power-to-weight ratio, and optimising body composition is likely to be beneficial when attempting to improve this determinant of performance.

On the flip side of that, body composition can be used to determine whether an athlete is fuelling sufficiently for performance. Research on the Female Athlete Triad has shown that low energy availability (as determined using kg of FFM) can have negative impacts on several health markers, such as bone density (4).

It is clear that body composition can provide valuable data for a number of athletes. An objective measure of body composition at baseline, and then at subsequent time points, can be helpful when determining an individual’s response to an intervention that has been put in place (e.g. a new diet plan). This is important as objective data clearly shows the efficacy of an intervention, if checked regularly, can allow for changes to be made.

How is body composition measured?

Body composition can be assessed in a number of different ways, with methods ranging in technicality, cost and accuracy. The only fully accurate measurement of body composition is cadaver whole-body dissection analysis, previously undertaken as part of the ‘Brussels Cadaver Analysis Study’ (5). In light of this, there are no in vivo techniques for body composition analysis that will provide complete accuracy, and so body composition assessment is an estimate, often made on assumptions regarding the proportions and properties of FM, FFM, water, protein, and other minerals.

Methods that are likely more accessible to the general public include skinfold calipers and bioelectrical impedance analysis, whereas research laboratories and elite sports teams may have access to hydrostatic weighing, DEXA, and Whole Body Plethysmography (BodPod). Each method has its pros and cons, and it is likely that there is no one technique that is optimal for all situations – this will be discussed in the following sections.

Dual-Energy X-Ray Absorptiometry (DEXA)
DEXA is based on a three-compartment model that measures bone mineral content, FM and FFM. A full body DEXA involves the individual lying on an open scanner for approximately eight minutes, whilst the ‘arm’ of the machine moves over the length of the body, and scans using two x-ray beams; the more energy that is absorbed, the denser the tissue. Two energies are used to allow estimates of soft tissue absorption, separate from bone (6).

DEXA is considered the gold standard measurement tool for the diagnosis of osteopenia and osteoporosis (7). It is fast, non-invasive, and only exposes individuals to a small amount of radiation. The DXA also has the added benefit of providing segmental body composition analysis, which may be of particular interest when looking at bone mineral density in some athletic populations.

Although it is often considered one of the most accurate methods of body composition analysis, it is not without limitations. In athletic populations, longitudinal data from repeated measurements of body composition may be affected by muscle glycogen levels, hydration status and changes in muscle metabolites such as creatine (8). This may lead to a misrepresentation of FFM, and these factors should be considered when interpreting the results of DXA estimates of body composition.

Skinfold Calipers
Skinfold calipers measure a double fold of skin and subcutaneous adipose tissue and apply constant pressure to the site. Skinfold measurements make the assumption that adipose tissue compresses in a predictable manner, that the thickness of the skin is negligible, and the double-layer compression is representative of an uncompressed single layer of adipose tissue. Measurements give results in millimetres, which can be then converted to a body fat percentage, with dozens of equations available for varying populations.

A potential limitation of skinfold measurements is that they are dependent on the competency and accuracy of the person taking the measurements (i.e. intra-rater reliability). To minimise the technical error of measurement, measurement sites and techniques have previously been defined (9). Practitioners can become accredited in anthropometric measurement through the International Society for the Advancement of Kinanthropometry (ISAK).

To qualify, practitioners must assess various skinfold sites, girths and breadths, and report values within 10 % of a Level 4 anthropometrist, and within 7.5 % of their own values when repeating measurements. Skinfold measurements taken just one centimetre away from the defined ISAK sites have previously been shown to produce significant differences in measurement values at each site, indicating how important it is to mark and measure skinfolds correctly for accurate data (10). Therefore, the intra-rater reliability of the test is extremely important.

Whole Body Plethysmography (BodPod)
Air-displacement plethysmography (ADP) can allow for the calculation of body composition through a 2-compartment model, based on assumptions of value constants for FM and FFM densities. ADP determines body volume by measuring the reduction in chamber volume caused by the introduction of a subject/athlete into a chamber with a fixed air volume (11). Body weight and body volume are determined by this method, with mass divided by volume providing a measure of density.

Again, this measurement is a non-invasive and quick method, with the advantage of not requiring exposure to radiation. BodPod has been shown to be a valid measure of group average body composition when compared to DEXA in female collegiate athletes (12). However, research has suggested a difference of 5.3 % between the BodPod and validated four-compartment models, with an error rate of 15 % (12). BodPod has also shown limited accuracy when attempting to determine changes over time (13), a primary consideration when choosing an assessment method for athletes.

Hydrodensitometry (Underwater Weighing)
Also known as ‘hydrostatic weighing’ or ‘underwater weighing’, hydrodensitometry works in a very similar way to the BodPod, in that it determines body volume, but this time based on how much water is displaced rather than air displacement. Body density is determined and then used to estimate body fat percentage. Again, this estimate is based on assumptions regarding the density of FFM, which may vary with age, gender, ethnicity and training status, potentially limiting its use in athletic populations (14).

Although this method was previously considered the gold standard by the American College of Sports Medicine, it is not without measurement error. The results are highly reliant on subject performance, and as the process itself is uncomfortable, it may take multiple tests to get a valid measurement. For example, measurement error can occur through unsuccessful attempts to blow all of the air out of the lungs, or air bubbles trapped in hair or swimsuits.

Bioelectrical Impedance Analysis (BIA)
BIA is based on the concept that electric current flows through the body at different rates depending on its composition (15). It involves running a light electrical current through the body and determining body composition through the resistance of the tissues to the electrical current. This provides a measure of total body water, which is converted to FFM on the assumption that 73 % of the body’s FFM is water (16). The low cost, speed of measurement and lack of need for technical expertise make BIA an attractive option for body composition measurement, particularly in epidemiological research. However, the accuracy of BIA is dependent on several factors, and as a result, it is likely the least valid measure of body composition discussed in this article.

BIA relies on empirical equations to estimate total body water, FFM and body cell mass; these equations use gender, age, weight, height and race as variables. Therefore, for BIA to be used as a valid measure of body composition, the correct equation must be used based on these factors (17). The validity of BIA in some populations has been questioned, particularly in obese patients (18), and in those with conditions that may alter fluid distribution, such as oedema (19).

BIA data is influenced by hydration status, and although the standardisation of fluid intake in the hours before testing may reduce the effects of hydration on body composition measurements, there is a lack of standardisation, or at least its reporting, in current research (20). This may also be true in applied practice with athletic populations. Exercise has been shown to lead to vast inaccuracies in body composition analysis using BIA (21), as has changes in hydration status (22). As a result, BIA may not be suitable for determining body composition changes due to fluctuations in hydration status following training.

Are there any issues with body composition testing?

Body composition measurement in vivo is an estimate. As mentioned previously, the cost and practicality of measuring body composition vary greatly, and often there is a trade-off between the two. Each method has a use in certain settings, and it is the job of the practitioner or user to understand the benefits and drawbacks of each method.

A further issue with body composition is often the focus of individuals on their absolute body fat percentage values. As highlighted previously, the variation in values can be significant, with differences in assessment method, the athlete’s physiological state and other assessment-specific variances affecting overall results. Rather than focusing on an absolute body fat number, it may be of more value to standardise measurement and track changes over time.

Is future research needed with body composition testing?

As measures of body composition are developed, more accurate measurements of FM and FFM can be established in various athletic populations. This means that future research should aim to determine:

  • Body composition reference values for a larger range of sports, including positional differences in sports where this may be significantly different.
  • How body composition may determine performance in these sports.
  • Aspects of an athlete’s lifestyle that may impact the validity of body composition, and how to standardise these factors to improve measurement accuracy.

Conclusion

There are a multitude of body composition assessment tools available to the practitioner, each with varying cost, accessibility and accuracy in each population. It is important to understand the benefits and limitations of each method, and how best to utilise each one in practice. Most assessment tools are useful in various settings, and accuracy can be improved with proper standardisation prior to testing.

Body Composition
  1. C. K. Wells and M. S. Fewtrell, “Measuring body composition,” Archives of Disease in Childhood, vol. 91, no. 7, pp. 612-617, 2006. https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2082845/
  2. Wang,, R. N. Pierson and S. B. Heymsfield, “The five-level model: a new approach to organizing body composition research,” American Journal of Clinical Nutrition, vol. 56, pp. 19-28, 1992. https://www.ncbi.nlm.nih.gov/pubmed/1609756
  3. Franchini, C. J. Brito and G. G. Artioli, “Weight loss in combat sports: physiological, psychological and performance effect,” Journal of the International Society of Sports Nutrition, vol. 9, p. 52, 2012. https://jissn.biomedcentral.com/articles/10.1186/1550-2783-9-52.
  4. B. Loucks, B. Kiens and H. H. Wright, “Energy availability in athletes,” Journal of Sport Sciences, vol. 29, pp. 7-15, 2011. https://www.ncbi.nlm.nih.gov/pubmed/21793767
  5. P. Clarys, A. D. Martin and D. T. Drinkwater, “Gross tissue masses in adult humans: data from 25 dissections,” Human Biology, vol. 56, pp. 459-473, 1984.
  6. Berger, “Bone Mineral Density Scans,” British Medical Journal, p. 484, 2002. https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1124002/
  7. Pisani, M. D. Renna, F. Conversano, E. Casciaro, M. Muratore, E. Quarta, M. Di Paola and S. Casciaro, “Screening and early diagnosis of osteoporosis through X-ray and ultrasound based techniques,” World Journal of Radiology, vol. 5, no. 11, pp. 398-410, 2013. https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3856332/
  8. L. Bone, M. L. Ross, K. A. Tomcik, W. G. Hopkins and L. M. Burke, “Manipulation of Muscle Creatine and Glycogen Changes DXA Estimates of Body Composition.,” Medicine and Science in Sport and Exercise, 2016. https://www.ncbi.nlm.nih.gov/pubmed/27898642
  9. J. Marfell-Jones, T. Olds, A. D. Stewart and L. Carter, International Standards for Anthropometric Assessment, Potchefstroom, South Africa: ISAK, 2006. http://www.ceap.br/material/MAT17032011184632.pdf
  10. Hume and M. Marfell-Jones, “The importance of accurate site location for skinfold measurement,” Journal of Sport Sciences, vol. 26, no. 12, pp. 1333-1340, 2008. https://www.ncbi.nlm.nih.gov/pubmed/18821122
  11. Dempster and S. Aitkens, “A new air displacement method for the determination of human body composition.,” Medicine and Science in Sport and Exercise, vol. 27, pp. 1692-1697, 1995. https://www.ncbi.nlm.nih.gov/pubmed/8614327
  12. P. Ballard, L. Fafara and M. D. Vukovich, “Comparison of Bod Pod and DXA in female collegiate athletes,” Medicine and Science in Sport and Exercise, vol. 36, no. 4, pp. 731-735, 2004. https://www.ncbi.nlm.nih.gov/pubmed/15064602
  13. A. Collins, M. L. Millard-Stafford, E. M. Evans, T. K. Snow, K. J. Cureton and L. B. Rosskopf, “Effect of race and musculoskeletal development on the accuracy of air plethysmography.,” Medicine and Science in Sport and Exercise, vol. 36, no. 6, pp. 1070-1077, 2004. https://www.ncbi.nlm.nih.gov/pubmed/1517917
  14. K. Mahon, M. G. Flynn, H. B. Iglay, L. K. Stewart, C. A. Johnson, B. K. McFarlin and W. W. Campbell, “Measurement of body composition changes with weight loss in postmenopausal women: comparison of methods,” The Journal of Nutrition, Health and Aging, vol. 11, no. 3, pp. 203-213, 2007. https://www.ncbi.nlm.nih.gov/pubmed/17508096
  15. M. Silva, C. N. Matias, D. A. Santos, P. M. Rocha, C. S. Minderico, D. Thomas, S. B. Heymsfield and L. B. Sardinha, “Do Dynamic Fat and Fat-Free Mass Changes follow Theoretical Driven Rules in Athletes?,” Medicine and Science in Sport and Exercise, vol. 49, no. 10, pp. 2086-2092, 2017. https://www.ncbi.nlm.nih.gov/pubmed/28542004
  16. Deghan and A. T. Merchant, “Is bioelectrical impedance accurate for use in large epidemiological studies?,” Nutrition Journal, vol. 7, p. 26, 2008. https://www.ncbi.nlm.nih.gov/pubmed/18778488
  17. Aragon, B. J. Schoenfeld, R. Wildman, S. Kleiner, T. VanDusseldorp, L. Taylor, C. P. Earnest, P. J. Arciero, C. Wilborn, D. S. Kalman, J. R. Stout, D. S. Willoughby, B. Campbell, S. M. Arent, L. Bannock, A. E. Smith-Ryan and J. Antonio, “International society of sports nutrition position stand: diets and body composition,” Journal of the International Society of Sports Nutrition, vol. 14, p. 16, 2017. https://jissn.biomedcentral.com/articles/10.1186/s12970-017-0174-y
  18. Deurenberg, M. Deurenberg-Yap and F. J. Schouten, “Validity of total and segmental impedance measurements for prediction of body composition across ethnic population groups.,” European Journal of Clinical Nutrition, vol. 56, no. 3, pp. 214-220, 2002. https://www.ncbi.nlm.nih.gov/pubmed/11960296
  19. Deurenberg, “Limitations of the bioelectrical impedance method for the assessment of body fat in severe obesity.,” American Journal of Clinical Nutrition, vol. 64, pp. 449-452, 1996. https://www.ncbi.nlm.nih.gov/pubmed/8780361
  20. J. Wu, J. J. Huang and C. Y. Lin, “Effects of fluid retention on the measurement of body composition using bioelectric impedance,” Journal of the Formosan Medical Association, vol. 93, pp. 939-945, 1994. https://www.ncbi.nlm.nih.gov/pubmed/7633198
  21. Brantlov, L. Jodal, A. Lange, S. Rittig and L. C. Ward, “Standardisation of bioelectrical impedance analysis for the estimation of body composition in healthy paediatric populations: a systematic review.,” Journal of Medical Engineering and Technology, vol. 41, no. 6, pp. 460-479, 2017. https://www.ncbi.nlm.nih.gov/pubmed/28585459
  22. M. Abu, M. J. McCutcheon, S. Reddy, P. L. Pearman, G. R. Hunter and R. L. Weinsier, “Electrical impedance in assessing human body composition: the BIA method,” American Journal of Clinical Nutrition, vol. 47, pp. 789-792, 1988. https://www.ncbi.nlm.nih.gov/pubmed/3364394
  23. Demirkan, M. Kutlu, M. Koz, M. Ozal, A. Gucluover and M. Favre, “Effects of hydration changes on body composition of wrestlers,” International Journal of Sports Studies, vol. 4, no. 1, pp. 196-200, 2014. https://www.researchgate.net/publication/279955916_Effects_of_hydration_changes_on_body_composition_of_wrestlers
  24. A. Tucker, J. D. Lecheminant and B. W. Bailey, “Test-retest reliability of the Bod Pod: the effect of multiple assessments,” Perceptual and Motor Skills, vol. 118, no. 2, pp. 563-570, 2014. https://www.ncbi.nlm.nih.gov/pubmed/24897887

Access our course on Agility for FREE!

Learn how to improve your athletes' agility. This free course also includes a practical coaching guide to help you design and deliver your own fun and engaging agility sessions.

Get Instant Access
Charlie Beestone

Charlie Beestone

Charlie has an MSc in Sport and Exercise Nutrition from Loughborough University. He has previously supported athletes in a variety of sports including canoeing, boxing, cricket, rugby league, Olympic weightlifting and strongwoman.

More content by Charlie
SFS Academy logo - white

Access our course on Agility for FREE!

Learn from a world-class coach how you can improve your athletes' agility. This course also includes a practical coaching guide to help you to design and deliver your own fun and engaging agility sessions.

Get Instant Access
Agility course devices